Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28.05.2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Reference substance name:
1,4-Benzenedicarboxylic acid, 1,4-diisononyl ester
EC Number:
700-453-0
Cas Number:
59802-05-0
Molecular formula:
C26H42O4
IUPAC Name:
1,4-Benzenedicarboxylic acid, 1,4-diisononyl ester
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
230 °C
Atm. press.:
1 013 mBar

Any other information on results incl. tables

   Flash point, corrected to a pressure of 1013 mbar [°C]
 Preliminary test  230.5
 First run  229.5
 Second run  230.5
 Mean value (of two runs)*  230.0

* rounded to ±0.5 °C

Applicant's summary and conclusion

Conclusions:
The flash point of the test item was determined according to EU test method A.9 [Directive 92/69/EEC, Official Journal L 383 A 1992] with the Pensky-Martens method (closed cup).
Flash point: 230,0 °C
Atmospheric pressure: 1013 mbar