Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01.09.2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
capillary viscometer (static)
Standard covering the apparatus used:
The determination of the kinematic viscosity was carried out by the capillary method with a viscosimeter according to Ubbelohde.

Test material

Constituent 1
Reference substance name:
1,4-Benzenedicarboxylic acid, 1,4-diisononyl ester
EC Number:
700-453-0
Cas Number:
59802-05-0
Molecular formula:
C26H42O4
IUPAC Name:
1,4-Benzenedicarboxylic acid, 1,4-diisononyl ester
Test material form:
liquid

Results and discussion

Viscosityopen allclose all
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
98.5
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
35.1

Any other information on results incl. tables

Apparatus: Viscosimeter AVS 470 (Schott) Temperatures: 20 °C and 40 °C

Temperature

20°C

40°C

1strun

313..83

360.45

2ndrun

313.54

361.04

3rdrun

313.77

360.33

4thrun

313.56

360.68

5thrun

314.43

360.17

Mean value of flow time [s]

313.83

360.53

Hagenbach correction [s]

0.000

0.002

Corrected flow time [s]

313.83

360.53

Viscosimeter constant [mm2s-2]

0.03139

0.09730

Kinematic viscosity [mm2s-1]

98.5

35.1

Applicant's summary and conclusion

Conclusions:
The kinematic viscosity of the test item was determined according to OECD guideline no. 114 [adopted on 12 May 1981] with the capillary viscosimeter method.
Kinematic viscosity at 20 °C: 98.5 mm2 s-1
Kinematic viscosity at 40 °C: 35.1 mm2 s-1