Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 10 of December 2018 to 07 March 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
23 March 2017
Type of method:
rotational viscometer (dynamic)

Test material

Constituent 1
Reference substance name:
Tetrakis(hydroxymethyl)phosphonium sulphate (2:1) and its oligomerisation products with urea
Molecular formula:
Not applicable
IUPAC Name:
Tetrakis(hydroxymethyl)phosphonium sulphate (2:1) and its oligomerisation products with urea
Test material form:
liquid
Remarks:
Aqueous solution
Details on test material:
- Name of test material (as cited in study report): Phosphonium, tetrakis (hydroxymethyl)-sulphate(2:1); polymer with urea
For others details see the section Confidential details on test material
Specific details on test material used for the study:
Name of test material (as cited in study report): Phosphonium, tetrakis (hydroxymethyl)-sulphate(2:1); polymer with urea

Results and discussion

Viscosityopen allclose all
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 66
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 31.5

Applicant's summary and conclusion

Conclusions:
The mean dynamic viscosity of the test item was 66.0 mPa.s at 20.0 °C ± 0.2 °C and 31.5 mPa.s at 40.0 °C ± 0.2 °C.
Executive summary:

The objective of the test was to determine the dynamic viscosity (η) of the test item expressed in mPa.s. The method used is the viscometer with rotational spindles. The rotation of the spindle submerged in the test item allows to measure the torsion strength necessary to overcome the resistance due to the viscosity.

Taking into account the results obtained at 20.0 °C and 40.0 °C, the test item was considered to have newtonian properties in the experimental conditions used.

The mean dynamic viscosity of the test item was 66.0 mPa.s at 20.0 °C ± 0.2 °C and 31.5 mPa.s at 40.0 °C ± 0.2 °C.