Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study conducted in a laboratory issued with a statement of compliance with GLP. Minimum details provided.
Qualifier:
according to
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
no
Remarks:
GLP compliant facility
Remarks on result:
other: The sample temperature did not reach 400°C by self-heating during the course of the test. The Relative Self-Ignition Temperature (RSIT) is >400 °C.

Minor exothermic decomposition was detected at 105 °C (FT=10K). A further exotherm occurred from 375 °C (FT=15K).

Conclusions:
The sample temperature did not reach 400°C by self-heating during the course of the test. The Relative Self-Ignition Temperature (RSIT) is >400 °C.

Description of key information

The sample temperature did not reach 400°C by self-heating during the course of the test. The Relative Self-Ignition Temperature (RSIT) is >400 °C.

Key value for chemical safety assessment

Additional information

Only a single study conducted according to guidelines is available for this endpoint. The study is considered to be relevant, reliable (Klimisch 1) and adequate for the purposes of risk assessment, classification and labelling.