Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
JUL - AUG 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
no
Type of method:
static method
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
9.5 mBar
Key result
Test no.:
#2
Temp.:
28.6 °C
Vapour pressure:
16.5 mBar
Key result
Test no.:
#3
Temp.:
35.3 °C
Vapour pressure:
19.7 mBar

The vapour pressure was determined by a static method.

Few grams of material were placed in a 50 ml glass bottle.

Glass bottle thermostated and system evacuated with a vacuum pump for 5 minutes.

Pressure measured with a pressure transmitter, Yokogawa no 918609418. Measuring up to 130 mBar.

Results at 20.0°C 9.5 mBar

28.6°C 16.5 mBar

35.3°C 19.7 mBar.

Conclusions:
Vapour pressure at
20.0°C: 9.5 mBar
28.6°C: 16.5 mBar
35.3°C: 19.7 mBar.
Executive summary:

The vapour pressure test was done according to OECD Guideline 104 using static method. Few grams of material were placed in a 50 ml glass bottle. Glass bottle thermostated and system evacuated with a vacuum pump for 5 minutes.


Vapour pressure at 20.0°C is 9.5 mBar, at 28.6°C is16.5 mBar and at 35.3°C is 19.7 mBar. 

Description of key information

The vapour pressure test was done according to OECD Guideline 104 using static method. Few grams of material were placed in a 50 ml glass bottle. Glass bottle thermostated and system evacuated with a vacuum pump for 5 minutes.


Vapour pressure at 20.0°C is 9.5 mBar, at 28.6°C is16.5 mBar and at 35.3°C is 19.7 mBar. 

Key value for chemical safety assessment

Vapour pressure:
950 Pa
at the temperature of:
20 °C

Additional information