Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

INHALATION

Remove from further exposure.  For those providing assistance, avoid exposure to yourself or others.  Use adequate respiratory protection.  If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance.  If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.

SKIN CONTACT

Wash contact areas with soap and water.  If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.  Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.

EYE CONTACT

Flush thoroughly with water for at least 15 minutes. Get medical assistance.

INGESTION

First aid is normally not required.  Seek medical attention if discomfort occurs.

MOST IMPORTANT SYMPTOMS AND EFFECTS, BOTH ACUTE AND DELAYED

Eye pain, redness, tearing, swelling of eyelids, itching. Local necrosis as evidenced by delayed onset of pain and tissue damage a few hours after injecton.

INDICATION OF ANY IMMEDIATE MEDICAL ATTENTION AND SPECIAL TREATMENT NEEDED

The need to have special means for providing specific and immediate medical treatment available in the workplace is not expected.

Fire-fighting measures

EXTINGUISHING MEDIA

Suitable Extinguishing Media:  Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Unsuitable Extinguishing Media:  Straight streams of water

SPECIAL HAZARDS ARISING FROM THE SUBSTANCE OR MIXTURE

Hazardous Combustion Products:  Smoke, Fume, Incomplete combustion products, Oxides of carbon

ADVICE FOR FIRE FIGHTERS

Fire Fighting Instructions:  Evacuate area.  Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply.  Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).  Use water spray to cool fire exposed surfaces and to protect personnel.

Accidental release measures

PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES

NOTIFICATION PROCEDURES

In the event of a spill or accidental release, notify relevant authorities in accordance with all applicable regulations.

PROTECTIVE MEASURES

Avoid contact with spilled material.  Additional protective measures may be necessary, depending on the specific circumstances and/or the expert judgment of the emergency responders.  

ENVIRONMENTAL PRECAUTIONS

Large Spills:  Dyke far ahead of liquid spill for later recovery and disposal.  Prevent entry into waterways, sewers, basements or confined areas.

METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP

Land Spill:  Stop leak if you can do so without risk.  Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers.  Recover by pumping or with suitable absorbent.

Water Spill:  Stop leak if you can do so without risk.  Confine the spill immediately with booms.  Warn other shipping.  Remove from the surface by skimming or with suitable absorbents.  Seek the advice of a specialist before using dispersants.

Water spill and land spill recommendations are based on the most likely spill scenario for this material; however, geographic conditions, wind, temperature, (and in the case of a water spill) wave and current direction and speed may greatly influence the appropriate action to be taken.  For this reason, local experts should be consulted.  Note:  Local regulations may prescribe or limit action to be taken.

Handling and storage

PRECAUTIONS FOR SAFE HANDLING

Prevent small spills and leakage to avoid slip hazard.  Material can accumulate static charges which may cause an electrical spark (ignition source).  When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations).  Use proper bonding and/or earthing procedures.  However, bonding and earthing may not eliminate the hazard from static accumulation.  Consult local applicable standards for guidance.  Additional references include American Petroleum Institute 2003 (Protection Against Ignitions Arising out of Static, Lightning and Stray Currents) or National Fire Protection Agency 77 (Recommended Practice on Static Electricity) or CENELEC CLC/TR 50404 (Electrostatics - Code of practice for the avoidance of hazards due to static electricity).    

Static Accumulator:  This material is a static accumulator.

CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES

The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabeled containers.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not Regulated for Land Transport
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not Regulated for Inland Waterways Transport
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Special provisions / remarks
Remarks:
SEA (MARPOL 73/78 Convention - Annex II):
Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not classified according to Annex II

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not regulated for Air Transport
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

ENGINEERING CONTROLS

The level of protection and types of controls necessary will vary depending upon potential exposure conditions.

Control measures to consider:  No special requirements under ordinary conditions of use and with adequate ventilation.

PERSONAL PROTECTION

Personal protective equipment selections vary based on potential exposure conditions such as applications, handling practices, concentration and ventilation.  Information on the selection of protective equipment for use with this material, as provided below, is based upon intended, normal usage.  

Respiratory Protection:  If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate.  Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable.

Types of respirators to be considered for this material include:  No protection is ordinarily required under normal conditions of use and with adequate ventilation.  

For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode.  Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.

Hand Protection:  Any specific glove information provided is based on published literature and glove manufacturer data.  Glove suitability and breakthrough time will differ depending on the specific use conditions.  Contact the glove manufacturer for specific advice on glove selection and breakthrough times for your use conditions.  Inspect and replace worn or damaged gloves.

The types of gloves to be considered for this material include:  No protection is ordinarily required under normal conditions of use.

Eye Protection:  Chemical goggles are recommended.

Skin and Body Protection:  Any specific clothing information provided is based on published literature or manufacturer data.  

The types of clothing to be considered for this material include:  No skin protection is ordinarily required under normal conditions of use.  In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.

Specific Hygiene Measures:  Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking.  Routinely wash work clothing and protective equipment to remove contaminants.  Discard contaminated clothing and footwear that cannot be cleaned.  Practice good housekeeping.

Stability and reactivity

REACTIVITY:  See sub-sections below.

CHEMICAL STABILITY:  Material is stable under normal conditions.

POSSIBILITY OF HAZARDOUS REACTIONS:  Not expected.

CONDITIONS TO AVOID:  Excessive heat. High energy sources of ignition.

INCOMPATIBLE MATERIALS:  Strong oxidisers

HAZARDOUS DECOMPOSITION PRODUCTS:  Material does not decompose at ambient temperatures

Disposal considerations

Disposal recommendations based on material as supplied.  Disposal must be in accordance with current applicable laws and regulations, and material characteristics at time of disposal.

WASTE TREATMENT METHODS

Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.

European Waste Code:  13 02 06*

NOTE:  These codes are assigned based upon the most common uses for this material and may not reflect contaminants resulting from actual use.  Waste producers need to assess the actual process used when generating the waste and its contaminants in order to assign the proper waste disposal code(s).

This material is considered as hazardous waste pursuant to Directive 91/689/EEC on hazardous waste, and subject to the provisions of that Directive unless Article 1(5) of that Directive applies.

Empty Container Warning

Empty Container Warning (where applicable):  Empty containers may contain residue and can be dangerous.  Do not attempt to refill or clean containers without proper instructions.  Empty drums should be completely drained and safely stored until appropriately reconditioned or disposed.  Empty containers should be taken for recycling, recovery, or disposal through suitably qualified or licensed contractor and in accordance with governmental regulations.  

DO NOT PRESSURISE, CUT, WELD, BRAZE, SOLDER, DRILL, GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS, STATIC ELECTRICITY, OR OTHER SOURCES OF IGNITION.  THEY MAY EXPLODE AND CAUSE INJURY OR DEATH.