Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Reliability rating was 2 because study followed OECD test guidelines and was carried out under GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
A mixture of isomers of: mono-(2-tetradecyl)naphthalenes; di-(2-tetradecyl)naphthalenes; tri-(2-tetradecyl)naphthalenes
EC Number:
410-190-0
EC Name:
A mixture of isomers of: mono-(2-tetradecyl)naphthalenes; di-(2-tetradecyl)naphthalenes; tri-(2-tetradecyl)naphthalenes
Cas Number:
132983-41-6
Molecular formula:
Can vary from C24H36 (mono rxn product) to C52H92 (tri rxn product)
IUPAC Name:
2,3,6-tritetradecylnaphthalene; 2,3-ditetradecylnaphthalene; 2-tetradecylnaphthalene
Constituent 2
Reference substance name:
MCP 2484
IUPAC Name:
MCP 2484

Results and discussion

Density
Type:
density
Density:
0.89 g/cm³
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
The density of the test material was determined to be 0.89 gm/ml at 20 degree C using the OECD 109 (pycnometer) test method.
Executive summary:

The density of the test material was determined to be 0.89 gm/ml at 20 degree C using the OECD 109 (pycnometer) test method.