Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1992
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Reliability rating was 1 because testing followed method equivalent to EU Method A.9 guidelines and was carried out under GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1992
Report date:
1992

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
closed cup
Remarks:
Pensky-Martens method

Test material

Constituent 1
Reference substance name:
MCP 968
IUPAC Name:
MCP 968
Constituent 2
Reference substance name:
132986-41-6
IUPAC Name:
132986-41-6

Results and discussion

Flash point
Flash point:
219 °C
Atm. press.:
1 030 mBar
Remarks on result:
other: Flash point was determined to be 219 C at 1030 mbar

Any other information on results incl. tables

see remarks and discussion above

Applicant's summary and conclusion

Conclusions:
The flash point of the test substance was determined to be 219 C at 1030 mbar
Executive summary:

The flash point of the test substance was determined to be 219 C at 1030 mbar..