Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2001
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Remarks:
Study performed similarly to OECD Guideline 114 with minor deviations: test was conducted at one temperature (25 °C) only; individual analytical determinations not reported
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
yes
Remarks:
test was conducted at one temperature (25 °C) only; individual analytical determinations not reported
Principles of method if other than guideline:
Not applicable
GLP compliance:
not specified
Type of method:
capillary viscometer (static)
Key result
Temp.:
other: 298.15K
Parameter:
dynamic viscosity (in mPa s)
Value:
0.846

Literature data (Brown et al.,1988): dynamic viscosity of (S)-(-)-limonene = 0.846 mPa.s

Conclusions:
Under the test conditions, the dynamic viscosity of (S)-(-)-limonene at 298.15 K was determined to be 0.8462 mPa.s.
Executive summary:

A study was conducted similarly to OECD Guideline 114 to determine the dynamic viscosity of (S)-(-)-limonene using Schott measuring system equipped with capillary viscometers. The kinematic viscosity was calculated from the average of six flow times using equation: ν = k (t – θ). The dynamic viscosity was calculated by the equation: η = ρν (ρ is density).  

 

Under the test conditions, the dynamic viscosity of (S)-(-)-limonene at 298.15 K was determined to be 0.8462 mPa.s.

Description of key information

Key study. Test method equivalent to OECD 114. Dynamic viscosity at 25°C : 0.8462 mPa.s.

Key value for chemical safety assessment

Viscosity:
0.846 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

The reported study is reliable with restrictions (Klimisch 2) having been conducted similarly to OECD 114 guideline with minor deviations.