Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2017-09-28 to 2018-02-23
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D 6378-2010‘Standard Test Method for Determination of Vapor Pressure (VPX) of Petroleum Products, Hydrocarbons, and Hydrocarbon-Oxygenate Mixtures (Triple Expansion Method)’
Version / remarks:
2010
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: GB/T 21616-2008 Dangerous goods-Test method for vapour pressure of flammable liquid
Version / remarks:
2008
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
other: Triple expansion method
Specific details on test material used for the study:
Batch No: 2270402
Purity: 99.72%
Key result
Temp.:
25 °C
Vapour pressure:
0.355 mm Hg
Remarks on result:
other: estimated by EPI SuiteTM (V 4.1) software

Based on the test result, the saturated vapor pressure of test item was below 7 kPa (ASTM D 6378-2010) at 37.8°C. From the further test, the saturated vapor pressure of test item was below 0.5 kPa (GB/T 21616-2008) at 37.8°C. Results of the saturation vapour pressure was estimated by EPI SuiteTM (V 4.1) software. The final value of saturation vapour pressure was 0.355 mmHg (exactly 47.3 Pa) at 25°C.

Conclusions:
The saturation vapour pressure of test item was estimated to be 0.355 mmHg (exactly 47.3 Pa) at 25°C.
Executive summary:

The Saturated Vapor Pressure Test of test item was determined according to ASTM D 6378-2010 and GB/T 21616-2008.

Based on the test result, the saturated vapor pressure of test item was below 7 kPa (ASTM D 6378-2010) at 37.8°C. From the further test, the saturated vapor pressure of test item was below 0.5 kPa (GB/T 21616-2008) at 37.8°C. Results of the saturation vapour pressure was estimated by EPI SuiteTM (V 4.1) software. The final value of saturation vapour pressure was 0.355 mmHg (exactly 47.3 Pa) at 25°C.

Description of key information

The saturation vapour pressure of test item was estimated to be 0.355 mmHg (exactly 47.3 Pa) at 25°C.

Key value for chemical safety assessment

Vapour pressure:
47.3 Pa
at the temperature of:
25 °C

Additional information

The Saturated Vapor Pressure Test of test item was determined according to ASTM D 6378-2010 and GB/T 21616-2008.

Based on the test result, the saturated vapor pressure of test item was below 7 kPa (ASTM D 6378-2010) at 37.8°C.

From the further test, the saturated vapor pressure of test item was below 0.5 kPa (GB/T 21616-2008) at 37.8°C.

Results of the saturation vapour pressure was estimated by EPI SuiteTM (V 4.1) software. The final value of saturation vapour pressure was 0.355 mmHg (exactly 47.3 Pa) at 25°C.