Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Principles of method if other than guideline:
Adapted due to high viscosity.Sample was heated to 60°C before test commenced to allow complete mixing Temperature range of 0 to 50 C used for the test.
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 520
Remarks on result:
other: Coverted from cPs

Kinematic density calculated using Density 0.992

Conclusions:
The substance is considered to be sufficiently viscous to avoid the requirement for classification as aspiration hazard.

Description of key information

Measured over a range of temperatures between ca 0 C to 50 C.

Kinematic viscosity calculated using density of 0.992 based on static viscosity of 524 mPa S

Key value for chemical safety assessment

Viscosity:
524 mPa · s (dynamic)
at the temperature of:
40 °C

Additional information

The kinematice viscosity of 532 mm2/s at 40 C greater than the limit for classification as aspiration toxic material.