Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Justification for type of information:
Testing for CAS 55184-72-0 is covered by tests with CAS 848588-96-5. Both substances are very similar since they differ mainly in the share of C13 (CAS 848588-96-5 C13> 80%; CAS 55184-72-0 > 95%). Hence, read across from CAS 848588-96-5 (source) to CAS 55184-72-0 (target) is considered as appropriate for both substances.
Reason / purpose for cross-reference:
read-across source
Boiling pt.:
>= 270 °C
Atm. press.:
997 mBar
Decomposition:
yes
Decomp. temp.:
>= 270 °C
Remarks on result:
other: From 270 °C the test item shows a boiling and/or thermal decomposition with evaporation of the decomposition components.

The test item Sodium bis(C11-14-isoalkyl, C13-rich) sulfosuccinate shows a boiling and/or thermal decomposition at ca. 270 °C (at 997 mbar) (a decomposition is most likely due to a strong residue in the crucible at ca. 600 °C) according to the definition in the OECD guideline 103 (mean value from repeat determination; 1st heating run).

·        272 °C (from first measurement)

·        269 °C (from second measurement)

From 270 °C the test item shows a boiling and/or thermal decomposition with evaporation of the decomposition components.

The DSC measurements were confirmed by means of TGA measurements (up to 270 °C the sample shows a weight loss of ca. 3-4 weight%) under the same measuring conditions.

Testing for CAS 55184-72-0 is covered by tests with CAS 848588-96-5. Both substances are very similar since they differ mainly in the share of C13 (CAS 848588-96-5 C13> 80%; CAS 55184-72-0 > 95%). Hence, read across from CAS 848588-96-5 (source) to CAS 55184-72-0 (target) is considered as appropriate for both substances.

Conclusions:
boiling/decomposition at 270°C
Executive summary:

In the Klimisch 1 non-GLP study from Kintrup (2013) the boiling point of Sodium bis(C11-14-isoalkyl, C13-rich) sulfosuccinate was determined with the DSC method according to OECD 103 and EU method A.2. The test item shows a boiling and/or thermal decomposition at ca. 270 °C (at 997 mbar) (a decomposition is most likely due to a strong residue in the crucible at ca. 600 °C) according to the definition in the OECD guideline 103 (mean value from repeat determination; 1st heating run).

This information is considered to be relevant and reliable for the further risk assessment.

Testing for CAS 55184-72-0 is covered by tests with CAS 848588-96-5. Both substances are very similar since they differ mainly in the share of C13 (CAS 848588-96-5 C13> 80%; CAS 55184-72-0 > 95%). Hence, read across from CAS 848588-96-5 (source) to CAS 55184-72-0 (target) is considered as appropriate for both substances.

Description of key information

boiling and/or thermal decomposition at ca. 270 °C

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
270 °C

Additional information

In the Klimisch 1 non-GLP study from Kintrup (2013) the boiling point of Sodium bis(C11-14-isoalkyl, C13-rich) sulfosuccinate was determined with the DSC method according to OECD 103 and EU method A.2. The test item shows a boiling and/or thermal decomposition at ca. 270 °C (at 997 mbar) (a decomposition is most likely due to a strong residue in the crucible at ca. 600 °C) according to the definition in the OECD guideline 103 (mean value from repeat determination; 1st heating run).

For the risk assessment a boiling point of 270°C will be used.

This information is considered to be relevant and reliable for the further risk assessment.