Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1993-04-19 to 1993-04-22
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes
Type of method:
pycnometer method
Key result
Type:
relative density
Density:
1.63 g/cm³
Temp.:
20 °C
Conclusions:
In a GLP study conducted according to OECD Guideline 109, the density of trisodium EDDS was 1.63 g/cm3 at 20°C
Executive summary:

In a GLP study conducted according to OECD Guideline 109, the density of trisodium EDDS was determined by gas comparison pycnometry at 20oC. The mean density (2 measurements) was 1.63 g/cm3

Description of key information

In a GLP study conducted according to OECD Guideline 109, the density of trisodium EDDS was 1.63 g/cm3 at 20°C

Key value for chemical safety assessment

Relative density at 20C:
1.63

Additional information

In a GLP study conducted according to OECD Guideline 109, the density of trisodium EDDS was determined by gas comparison pycnometry at 20°C. The mean density (2 measurements) was 1.63 g/cm3 (van Helvoirt, 1993b).

 

In addition, in a GLP study conducted according to EU Method A.3, the relative density of EDDS acid was determined, on two occasions, using the pycnometer method. The mean density was calculated as 1.59 g/cm3at 19°C (Gair et al. 2002). [Data on EDDS free acid is considered relevant to use for understanding the potential vapour pressure of trisodium EDDS, and is acceptable for using as read-across information.]