Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 26/07/2018 to 02/11/2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
no
Type of method:
static method
Key result
Temp.:
20 °C
Vapour pressure:
11.3 Pa
Conclusions:
The vapour pressure of the test item was 11.3 Pa at 20ºC.
Executive summary:

The vapour pressure of the test item was determined by the Static method.

The test was conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A.4.

The vapour pressure of the test item was determined to be 11.3 Pa at 20ºC.

Description of key information

Vapour pressure: 11.3 Pa at 20ºC.

Key value for chemical safety assessment

Vapour pressure:
11.3 Pa
at the temperature of:
20 °C

Additional information

The vapour pressure of the test item was determined by the Static method.

The test was conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A.4.