Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: MINIFLASH automatic flash point tester

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: M-1025-157
- Expiration date of the lot/batch: 25 October 2018


Results and discussion

Flash point
Key result
Flash point:
< 200 °C
Remarks on result:
no flash point according to standard method

Any other information on results incl. tables

 Preliminary test was performed from 30 to 200 °C with negative result. The test item was measured in the main test with two parallel tests from 185 °C.

The measured flash point of Ethoxylated phenol phosphate was: no flash point was observed up to 200°C.

Applicant's summary and conclusion

Interpretation of results:
study cannot be used for classification
Conclusions:
The measured flash point of Ethoxylated phenol phosphate was: no flash point was observed up to 200°C using MINIFLASH automatic flash point tester, according to EU A.9.
Executive summary:

The measured flash point of Ethoxylated phenol phosphate was: no flash point was observed up to 200°C using MINIFLASH automatic flash point tester, according to EU A.9.