Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
other: DIN 51758 Testing of liquid petroleum products and other combustible liquids; determination of flash point by pensky-martens closed tester
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks on result:
no flash point up to 100°C
Interpretation of results:
other: not classified, according to the CLP Regulation (EC) 1272/2008
Conclusions:
No flash point up to 100 °C
Executive summary:

The flash point was tested according to the DIN 51758 method, testing of liquid petroleum products and other combustible liquids; determination of flash point by pensky-martens closed tester. No flash point was recorded up to 100 °C.

Conclusion

No flash point up to 100 °C, thus the substance does not meet the criteria to be classified as flammable liquid, according to the CLP Regulation (EC) No 1272/2008.

Description of key information

No flash point up to 100 °C

Key value for chemical safety assessment

Additional information

DIN 51758 method