Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009/05/20
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D97-08 (POUR POINT)
Deviations:
no
GLP compliance:
no
Type of method:
pour point

Test material

Constituent 1
Reference substance name:
Alkenes, C11-12, hydroformylation products, low boiling
EC Number:
932-235-8
Molecular formula:
Non available- not a single isomer
IUPAC Name:
Alkenes, C11-12, hydroformylation products, low boiling
Details on test material:
- Name of test material (as cited in study report): ALCHISOR TAL 123
- Substance type: Product
- Physical state: liquid
- Lot/batch No.: 53071

Results and discussion

Melting / freezing point
Melting / freezing pt.:
-36 °C
Atm. press.:
ca. 1 atm
Decomposition:
no
Sublimation:
no

Any other information on results incl. tables

CALIBRATION

(repeat determination)

Substance used for calibration: Decane RS309051

Melting point (theory): -29.7°C

Melting point (experimental): -30 °C

MEASUREMENT

(repeat determination)

POUR POINT: -36°C

Applicant's summary and conclusion

Conclusions:
Average pour point: -36 °C at atmospheric pressure.
Executive summary:

Alkenes, C11-12, hydroformylation products, low boiling is measured according to ASTM D97 -08. The pour point is detected to be -36 °C at atmospheric pressure.