Registration Dossier

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Not oxidizing

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

The determination was performed according to EEC Directive 84/449, A.17.

In the full test, the maximum burning rate of test substance mixture is lower than the maximum burning rate of the reference mixture. The ratio was calculated to be 0.35

Based on the criteria as outlined in the OECD Guideline the test substance is not to be considered as an oxidizing substance.

Justification for classification or non-classification

As the experimental data provided the substance is not considered to be classified as an oxidising material