Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
4 (not assignable)

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1992

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: Annex V, A10
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: No higly flammable
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Substances / mixtures which in contact with water emit flammable gases
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information