Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Study test phase 2012-05-02 to 2012-05-04. Study report 2012-08-16.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Meets the criteria as reliable without restriction according to Klimisch et al (1997).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Deviations:
no
GLP compliance:
yes
Type of method:
HPLC estimation method
Media:
other: HPLC column

Test material

Constituent 1
Chemical structure
Reference substance name:
lithium 3-((3,4-dicyanophenyl)sulfonyl)propane-1-sulfonate)
EC Number:
700-777-2
Cas Number:
667889-11-4
Molecular formula:
C11H9N2O5S2Li
IUPAC Name:
lithium 3-((3,4-dicyanophenyl)sulfonyl)propane-1-sulfonate)
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Radiolabelling:
no

Study design

Test temperature:
19.92 to 20.72 deg. C

HPLC method

Details on study design: HPLC method:
EQUIPMENT
- Apparatus: A HPLC comprising of HPLC pump, Injection valve fitted with 100ul loop, 250 x 4.6mm column packed with a 5 um CN phase, PDA scan 210nm to 400nm and chromotography data system.

MOBILE PHASES
- Type: 55% methanol and 45% deionised water pumped through at a flow rate of 1.5 ml/min
- pH: pH range 5.5 to 7.5

DETERMINATION OF DEAD TIME
- Method: by inert substances which are not retained by the column (sodium nitrate)

REFERENCE SUBSTANCES
- Identity: Acetanilide, Atrazine, Isoproturon, Linuron, Naphthalene, 1,2,3-Trichlorobenzene, Fenthion, Phenanthrene, ppDDT

EVALUATION
- Calculation of capacity factors k': k'= (retention time of test substance - column dead time)/ column dead time
- Calculation of retention times: All the reference substances were injected in duplicate, and the mean retention times were determined, Each concentration of test material (5.0 and 10 mg/L) was also injected in duplicate and the mean retention time determined for each concentration.
- Determination of the log Koc value: Determined from the equation of the line from the calibration graph of logKoc versus logk'

Batch equilibrium or other method

Analytical monitoring:
no

Results and discussion

Adsorption coefficientopen allclose all
Type:
log Koc
Value:
< 1.5
Remarks on result:
other: 5.0 mg/L
Type:
log Koc
Value:
< 1.5
Remarks on result:
other: 10 mg/L

Results: HPLC method

Details on results (HPLC method):
- Retention times (s) of reference substances used for calibration:
Acetanilide 171
Atrazine 269
Isoproturon 288
Linuron 475
Naphthalene 364
1,2,3-Trichlorobenzene 507
Fenthion 846
Phenanthrene 948
ppDDT 3116

- Details of fitted regression line (log k' vs. log Koc): y=2.74172x+ 1.35936 r2= 0.95418

- Average retention data for test substance(s): 10 mg/L 81, 5.0mg/L 79

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
The log10k' for the test substance could not be calculated at either test concentration (5.0mg/L and 10mg/L) because the peak eluted before the sodium nitrate peak, therefore, it is outside the range and accordingly the estimated log10Koc for the test material is reported as <1.5.
Executive summary:

Introduction

This study was performed to estimate the adsorption coefficient (Koc) of the test material using a high performance liquid chromotography (HPLC) correlation technique. The method was designed to be compatible with:

-OECD Test Guideline 121, Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using HIgh Performance Liquid Chromotography (HPLC)

Results & Conclusions

The log10k' for the test substance could not be calculated at either test concentration (5.0mg/L and 10mg/L) because the peak eluted before the sodium nitrate peak, therefore, it is outside the range and accordingly the estimated log10Koc for the test material is reported as <1.5.