Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Study started 8-05-2012 , experimental complete 10-08-2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and the study was conducted under GLP conditions.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
GLP compliance:
yes
Type of method:
plate method

Test material

Constituent 1
Chemical structure
Reference substance name:
lithium 3-((3,4-dicyanophenyl)sulfonyl)propane-1-sulfonate)
EC Number:
700-777-2
Cas Number:
667889-11-4
Molecular formula:
C11H9N2O5S2Li
IUPAC Name:
lithium 3-((3,4-dicyanophenyl)sulfonyl)propane-1-sulfonate)
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Surface tension
Key result
Surface tension:
72.1 mN/m
Temp.:
25 °C
Conc.:
1 g/L

Any other information on results incl. tables

Mean Surface Tension: 72.1 mN/m

Test 1: 72.06 mN/m at 25 plus or minus 0.5°C (using mean of last 10 values)

Test 2: 72.12 mN/m at 25 plus or minus 0.5°C (using mean of last 10 values)

The confidence interval for the method is +0.9% which for a mean of 72.1mN/m equals to 0.6mN/m

Applicant's summary and conclusion

Conclusions:
The confidence interval for the method is + 0.9% The mean surface tension is 72.1mN/m .
Test 1 :72.06mN/mat 25 degrees C plus or minus 0.5
Test 2: 72.12mN/m at 25 degrees C plus or minus 0.5

Executive summary:

Introduction

This study was undertaken to determine the surface tension of the test material. The test method was designed to be in accordance with OECD Guideline 115.

Results & Conclusions

The mean surface tension in this study was 72.1mN/m. The test material is not surface active.