Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Qualifier:
according to guideline
Guideline:
ISO 13736 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Abel apparatus
Remarks:
and Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
2-cyano-N-methylacetamide
EC Number:
228-705-0
EC Name:
2-cyano-N-methylacetamide
Cas Number:
6330-25-2
Molecular formula:
C4H6N2O
IUPAC Name:
2-cyano-N-methylacetamide
Test material form:
liquid

Results and discussion

Flash pointopen allclose all
Remarks on result:
no flash point according to standard method
Remarks:
igniting flame extinguished at ca. 45°C by ISO 2719
Remarks on result:
no flash point according to standard method
Remarks:
igniting flame extinguished at 67°C by ISO 13736

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met