Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
GLP compliance:
no
Type of method:
closed cup
Flash point:
102.1 °C
Atm. press.:
1 013 mBar

Atmospheric pressure: 1010 mbar


Flash point at the ramp mode 104ºC


 


Flash point at the automatic mode:


Determination 1: 102ºC


Determination 2: 102ºC


 


Mean Flash point: 102 ± 0ºC


Flash point after adjustment to an atmospheric pressure of 1013 mbar: 102.1 ± 0.0ºC

Interpretation of results:
other: EU GHS criteria not met
Remarks:
EU GHS criteria not met
Conclusions:
The flashpoint at 1013 mbar: 102.1 ± 0.0ºC
Executive summary:

Flash point test was done according to EU Method A.9 without GLP compliance. Flash point of test item was determined as 102.1 ± 0ºC at 1013mbar. Test item is not subject to hazard class 'flammable liquid' according to EU GHS criteria.

Description of key information

Flash point test was done according to EU Method A.9 without GLP compliance. Flash point of test item was determined as 102.1 ± 0ºC at 1013mbar. Test item is not subject to hazard class 'flammable liquid' according to EU GHS criteria.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
102.1 °C

Additional information