Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
May 2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
no
Type of method:
thermal analysis
Remarks:
ASTM D3418
Remarks on result:
other: MPK, no melting can be found, even cooled @.1°C/min. No Tg can be found in this temperature range between -80°C and 25°C.

*INFORMATION REQUIREMENTS-Corresponds to solid/liquid phase change at atmospheric pressure. Study does not need to be conducted below a lower limit of -20 °C.

 

METHOD

 

The melting point was determined using a TA Instruments Q2000 DSC equipped with a Liquid Nitrogen Cooling System with a Heat-Cool-Heat method which conforms to ASTM D3418.

 

PROCEDURE

 

DSC is calibrated @ 10°C/min. with Alfa Aesar’s Adamantane, 98%, Stock #A14041, CAS#281-23-2, for onset of melting @ -65.54°C +/-0.4°C and NIST’s Indium for onset of melting @ 156.60°C +/- 0.4°C and constant for Heat of Fusion of 6.8 cal/g. The instrument is purged with Helium @ 50 c.c./min. and scanning rates for heating is 10°C/min. and cooling rates are 0.1.  Sample was encapsulated in TA’s Tzero Aluminum pan and Tzero hermetic Aluminum lid. For liquid samples, the temperature range was from -80°C to 25°C. For others, the temperature range was from -50°C to 200°C or 220°C.

 

CALCULATIONS

 

Due to the unknown heat history of the sample, only the 2ndheating scan was used for the calculation. The onset of melting peak temperature, Tonset, and melting peak temperature,

Tm, as well as onset of Tg were analyzed using TA Instruments Universal Software V4.7A. 

 

RESULTS/CONCLUSION

 

For LIMS#483977: MPK, no melting can be found, even cooled @.1°C/min. No Tg can be found

                                            in this temperature range between -80°C and 25°C.

 

Conclusions:
MPK, no melting can be found, even cooled @.1°C/min. No Tg can be found in this temperature range between -80°C and 25°C
Executive summary:

MPK, no melting can be found, even cooled @.1°C/min. No Tg can be found in this temperature range between -80°C and 25°C

Description of key information

MPK, no melting can be found, even cooled @.1°C/min.  No Tg can be found in this temperature range between -80°C  and 25°C.

Key value for chemical safety assessment

Additional information