Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 16, 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2015
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
other: • Normalab NPV310
Key result
Remarks on result:
no flash point - measurement carried out until boiling temperature

The following tables show the results of the measurements as temperatures where ignition (+) was detected and where not (-).
Table 1 shows the results from the flash point measurements:
Table 1: Preliminary test

Test item / mL Starting temperature / °C Temperature / °C Ignition + / -
2 -30 - -
2 -30 - -
2 -30 - -

No flash point was observed up to 61 °C. Above 61 °C the test item was evaporated and thus the vessel was empty. The main test was not necessary.

Executive summary:

No flash point was observed up to 61 °C. Above 61 °C the test item was evaporated.

Description of key information

No flash point was observed up to 61 °C. Above 61 °C the test item was evaporated.

Key value for chemical safety assessment

Additional information