Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-07-20
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was conducted in accordance with a relevant test method and in compliance with a known quality system (ISO 9001:2008)
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
DIN 51562
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2008
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.6

Test: 1

Capillary tube: Ic

Correction factor: 0.02991

Measured time [s]

Mean value [s]

129

128

123

120

120

124

 

Calculation:

Viscosity [mm2/s]: time (mean value) x correction factor = viscosity = 3.7088

 

 

Test: 2

Capillary tube: I

Correction factor: 0.009678

Measured time [s]

Mean value [s]

361

361

361

361

361

361

 

Calculation:

Viscosity [mm2/s]: time (mean value) x correction factor = viscosity = 3.4938

 

Conclusions:
A kinematic viscosity value of 3.6 mm2/s at 20°C was determined for the substance using a relevant test method and in compliance with a known quality system. The result is considered to be reliable.

Description of key information

Kinematic viscosity: 3.6 mm2/s at 20°C (DIN 51562)

Key value for chemical safety assessment

Viscosity:
3.6 mm²/s (static)
at the temperature of:
20 °C

Additional information

A kinematic viscosity value of 3.6 mm2/s at 20°C was determined for the substance using a capillary viscometer in accordance with a relevant test method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable.