Description of key information

According to column 2 of Annex VII of the REACH regulation the study does not need to be conducted as the substance is hydrolytically unstable. The hydrolysis product aniline has a water solubility of 35 g/L at 20°C.

Key value for chemical safety assessment

Water solubility:
35 g/L
at the temperature of:
20 °C

Additional information

According to column 2 of Annex VII of the REACH regulation the study does not need to be conducted as the substance is hydrolytically unstable.

Therefore a read across approach is applied based on the following assumption:

According to handbook data, isocyanates react rapidly with water forming aminic structures as well as carbamic acids, which are mostly unstable, and ureas under release of carbon dioxide. Monitoring the amine formation in hydrolysis studies gives a picture of the degradation of the isocyanate. This behaviour of isocyanates has been used in studies to determine the rate of degradation*. In Guidance on IR & CSA Chapter R.6 it is mentioned that degradation products instead of parent substance can be investigated for ecotoxicological effects if the hydrolysis is very rapidly (t1/2 <1 h), OECD Guidance Document on Aquatic Toxicity Testing of Difficult Substances and Mixtures (2000) and Guidance on IR & CSA Chapter R.7b state the same. As phenyl isocyanate hydrolyses to aniline this is the ecotoxicological relevant species. Concluding, tests performed using the corresponding amine can equally be used to assess the ecotoxicological hazards of phenyl isocyanate. An underestimation of environmental hazards is thus avoided supporting a conservative and thus protective hazard assessment.

* Bayer Industry Services (2004), 4-chlorophenyl-isocyanate: Investigation on Stability in Aqueous Test Solutions. Project No: 200300181. Leverkusen, Germany.

Bayer Industry Services (2003), Isopropyl isocyanate: Investigation on Stability in Aqueous Test Solutions. Project No: 200300095. Leverkusen, Germany.