Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July - September 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
not specified
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester
Flash point:
244 °C
Atm. press.:
1 atm

The flash-point of the test item is the lowest temperature at which the test item evolves vapours in such amount that a flammable vapour/air mixture is produced in the test vessel.

Conclusions:
The flash-point of the test item was 244°C.
Executive summary:

The closed cup method was applied for the determination of the flash-point.

The flash-point of the test item was 244°C.

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
244 °C