Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is marketed or used in a non solid or granular form
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Production description by manufacturer
Qualifier:
no guideline followed
Principles of method if other than guideline:
Primary observations
GLP compliance:
no
Specific details on test material used for the study:
Sample prepared specifically with no solvent; typically manufactured in solvent
Physical state at 20°C and 1013 hPa:
liquid
Key result
Form:
liquid
Colour:
Light yellow / brown
Substance type:
organic
Conclusions:
Clear light coloured liquid

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion