Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 Apr 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
GLP guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
adopted in 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
adopted in 1995
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
National Institute of Pharmacy and Nutrition, Budapest, Hungary
Type of method:
oscillating densitimeter
Key result
Type:
relative density
Density:
ca. 1.009 other: dimensionless
Temp.:
20 °C

Results

The density of the test item was determined with the help of DMA-500 density meter.

The results are summarized in the following table.

Density (g/cm3)

1.0103

1.0090

1.0069

1.0097

1.0095

1.0093

Average

1.009

Standard deviation

0.0012

95% Confidence interval

0.0015

Description of key information

Relative density at 20.0 °C is 1.009 (OECD Guideline 109 (Density of Liquids and Solids), EU Method A.3 (Relative Density), oscillating densitimeter)

Key value for chemical safety assessment

Relative density at 20C:
1.009

Additional information