Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study report available

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report Date:
2007

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
>= 272 s
Remarks on result:
other: the test substance was not highly flammable

Any other information on results incl. tables

The test substance ignited and propagated a flame over 200 mm in 272 seconds. As the burn time was greater than 240 seconds in this preliminary test, no further testing was necessary.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test substance has not be classified as highly flammable according to regulation (EC) No. 1272/2008.
Executive summary: