Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.
Qualifier:
according to
Guideline:
other: ASTM D 2879
Deviations:
no
GLP compliance:
no
Type of method:
isoteniscope
Key result
Temp.:
ca. 38 °C
Vapour pressure:
< 0.001 mBar
Remarks on result:
other: < 0.001 mmHg at 100 °F

Description of key information

< 0.001 mbar at ca. 38 °C (100 °F)

Key value for chemical safety assessment

Vapour pressure:
0.1 Pa
at the temperature of:
422 K

Additional information