Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes
Specific details on test material used for the study:
The batch of Disperse Brown 27 (4852-1501) tested was a brown powder with a purity of 99.7 %
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
ca. 4 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item melted, burned with a yellow flame, emitted sparks and turned into a black residue. Brown smoke was observed. After removal of the ignition source, the flame extinguished after 2 seconds and no propagation of combustion was observed. Test item deemed not highly flammable
Executive summary:

The test item melted, burned with a yellow flame, emitted sparks and turned into a black residue. Brown smoke was observed. After removal of the ignition source, the flame extinguished after 2 seconds and no propagation of combustion was observed. No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required.Test item deemed not highly flammable

Description of key information

The test item melted, burned with a yellow flame, emitted sparks and turned into a black residue. Brown smoke was observed. After removal of the ignition source, the flame extinguished after 2 seconds and no propagation of combustion was observed. No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Test item deemed not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The test item melted, burned with a yellow flame, emitted sparks and turned into a black residue. Brown smoke was observed. After removal of the ignition source, the flame extinguished after 2 seconds and no propagation of combustion was observed. No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required.Test item deemed not highly flammable

Justification for classification or non-classification

The test item melted, burned with a yellow flame, emitted sparks and turned into a black residue. Brown smoke was observed. After removal of the ignition source, the flame extinguished after 2 seconds and no propagation of combustion was observed. No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required.Test item deemed not highly flammable