Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. QA statement)
Type of method:
dynamic method
Remarks:
Grain-Watson estimation

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
<= 0.01 Pa

Applicant's summary and conclusion

Conclusions:
The test item has a vapour pressur of <= 0.0099 Pa.