Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-12-22
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The information is based on a reliable non-GLP in-house study using the closed cup method equivalent to EU A.9 (Flash-Point).
Qualifier:
equivalent or similar to
Guideline:
EU Method A.9 (Flash-Point)
Principles of method if other than guideline:
ASTM Standard: D6450-99 Standard test method for Flashpoint by Continuously Closed Cup (CCCFP) tester. Apparatus used: Grabner Miniflash FLP or FLPL (or Equivalent).
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
134 °C
Atm. press.:
101 300 Pa
Conclusions:
The Flash Point of OTNE is 134°C. in a reliable non-GLP study using the closed cup method equivalent to the EU Method A.9 (Flash-Point).

Executive summary:

The Flash Point of OTNE is 134°C using the closed cup method study equivalent to EU Method A.9 (Flash-Point).

Description of key information

The Flash Point of OTNE is 134°C using the closed cup method study equivalent to EU Method A.9 (Flash-Point).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
134 °C

Additional information