Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
GLP compliance:
yes (incl. QA statement)
Type of method:
column elution method
Water solubility:
0.44 mg/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
>= 6.2 - <= 7.4

Fractions used for the determination of the water solubility

Column 1 (12 mL/h)  

 Fraction no. pH value  Concentration [mg/L]
 11  7.0 0.451879 
 12 7.0   0.443590
 13  7.1  0.445686
 14  6.8  0.443197
 15 7.4 

 0.445771

Column 2 (24 mL/h)

 Fraction no. pH value  Concentration [mg/L]
 3  7.0 0.424472 
 4 6.2   0.424415
 5  6.9  0.426941
 6  7.0  0.420873
 7 7.0

 0.428611

Conclusions:
The water solubility of Macrolex Orange R was determined as 0.44 mg/L.
Executive summary:

The water solubility of Macrolex Orange R was determined by the column elution method according to OECD Guideline 105, EC Guideline A.6.

The test item was eluted with water from a micro-column charged with silica gel, which was previously coated with an excess of the test item. At 20 °C fractions were collected at a flow rate of 12 mL/h (column 1) and at a flow rate of 24 mL/h (column 2). For each fraction 10 mL were collected. After dilution with acetonitrile the concentration of the test item in the solutions was determined by HPLC-UV-analysis. The water solubility was determined as 0.44 mg/L.

Description of key information

The water solubility of Macrolex Orange R was determined by the column elution method according to OECD Guideline 105, EC Guideline A.6.

The test item was eluted with water from a micro-column charged with silica gel, which was previously coated with an excess of the test item. At 20 °C fractions were collected at a flow rate of 12 mL/h (column 1) and at a flow rate of 24 mL/h (column 2). The water solubility was determined as 0.44 mg/L by HPLC-UV-analysis.

Key value for chemical safety assessment

Water solubility:
0.44 mg/L
at the temperature of:
20 °C

Additional information