Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Starting Date: 02 November 2012 Experimental Completion Date: 07 November 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and the study was conducted under GLP conditions.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes
Type of method:
pycnometer method

Test material

Constituent 1
Test material form:
liquid
Specific details on test material used for the study:

Identification: Hydroxybutyl Methacrylate
Description: Clear colorless liquid
Sponsors Lot number: 57821
Sigma-Aldrich Lot number: MKBH4325V
Purity: 98.5%
Expiry / Retest Date: 02 October 2013
Storage Conditions: Approximately 4 °C, in the dark

Results and discussion

Density
Type:
relative density
Density:
1.01
Temp.:
20 °C

Any other information on results incl. tables

Results

Results of duplicate determinations of density are shown in the following table:

 

Table 3.1

 

Measurement

Determination

1

2

Mass of pycnometer (g)

18.2219

17.3280

Mass of pycnometer and purified water at 20.0 ºC (g)

28.1422

27.5167

Mass of pycnometer and test item at 20.0 ºC (g)

28.2674

27.6539

Density of water at 20.0 ºC (kg/m3)

0.99820

0.99820

Density (kg/m3)

1.011 x 103

1.012 x 103

Relative density

1.011

1.012

 

Mean relative density:            1.01
Temperature:                         20.0 ± 0.5 ºC

Applicant's summary and conclusion

Conclusions:
The relative density of the test item has been determined to be 1.01 at 20.0 ± 0.5 °C.
Executive summary:

The determination was carried out using the pycnometer method, designed to be compatible with Method A3 Relative Density of Commission Regulation (EC) No 440/2008 of 30 May 2008.

 

Conclusion

The relative density of the test item has been determined to be 1.01 at 20.0 ± 0.5 °C.