Registration Dossier

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The endpoint is waived: The substance decomposes before boiling.

Key value for chemical safety assessment

Additional information

The Self-Accelerating Decomposition Temperature (SADT) of the substances is 30°C (reference SADT: CLP regulations 2.15.2.3 and UN Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, 5th revised edition, sub-sections 28.1, 28.2, 28.3 and Table 28.3.)

According to ECHA Guidance on information requirements and chemical safety assessment.Chapter R.7a p 53: A study does not need to be conducted for substances which decompose before boiling.