Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 November 2009 - 15 January 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
76 °C
Atm. press.:
1 008 mBar
Remarks on result:
other: Result of duplicate determinations
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of MMB-Ac was found to be 76°C.

Description of key information

The flash point of MMB-AC was found to be 76°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
76 °C

Additional information

The barometric pressure at the time of testing was 1008 mbar and, thus, no pressure correction was required.