Registration Dossier

Administrative data

Endpoint:
hydrolysis
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is highly insoluble in water
other:
Cross-reference
Reason / purpose:
reference to other study
Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
flask method
Key result
Water solubility:
< 0.5 mg/L
Conc. based on:
test mat.
Loading of aqueous phase:
100 mg/L
Incubation duration:
24 h
Temp.:
20 °C
pH:
7
Remarks on result:
not determinable
Remarks:
below limit of detection
Conclusions:
the concentration in the water phase of ws below limit of detection (0.1 mg Sn / L)