Registration Dossier

Administrative data

Endpoint:
boiling point
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a solid which melts above 300°C
Cross-reference
Reason / purpose:
reference to other study
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
318 °C
Atm. press.:
1 028 hPa
Decomposition:
no
Conclusions:
the melting point was determined to be 318 °C

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion