Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 April 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
not specified
GLP compliance:
yes
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
2-phenoxyethanol; phosphoric acid
EC Number:
609-691-9
Cas Number:
39464-70-5
Molecular formula:
(C2-H4-O)mult-C6-H6-O.x-H3-O4-P
IUPAC Name:
2-phenoxyethanol; phosphoric acid

Results and discussion

Density
Key result
Type:
relative density
Density:
ca. 1 218 kg/m³
Temp.:
20 °C

Any other information on results incl. tables

Determining the Density of the Immersion Liquid

Mass of Empty Pycnometer (g)

24.07

Volume of Pycnometer (ml)

25.3

Mass water & Pycnometer (g)

49.34

Density of Water (g/cm3) (rW,t)

0.998

Mass of IL & Pycnometer (g)

49.34

Mass IL in Pycnometer (g) (m1)

25.26

Calculated Density of IL (g/cm3)

0.998

Density of IL (kg/m3)

998

 

Equation 1 (Calculation for the density of water):

Mass of water / volume of pycnometer = Density of water

 

Equation 2 (Calculation for the density of immersion liquid):

 

PIL = (m1/ mW) x PW,t

 

Where:

m1 is the mass of the immersion liquid

mW is the mass of water

PW,t is the density of water at temperature t

 

Determining the Density of the Sample

Run Number

1

 

2

Mass of Empty Pycnometer (g)

24.07

 

24.07

Mass of Sample & Pycnometer (g)

54.87

 

54.91

Mass of Sample added to empty Pycnometer (g) ms

30.79

 

30.84

Calculated Density of Sample(g/cm3)

1.217

 

1.218

Density of Sample (kg/m3)

1217

 

1218

Mean Result (kg.m-3)

 

1218

 

Applicant's summary and conclusion

Conclusions:
The relative density was measured to be 1218 kg.m-3 @ 20°C using the method according to EU Regulation (EC) 440/2008, Annex Part A test A3 and OECD Test Guideline 109.
Executive summary:

The relative density was measured to be 1218 kg.m-3 @ 20°C using the method according to EU Regulation (EC) 440/2008, Annex Part A test A3 and OECD Test Guideline 109.