Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: MINIFLASH automatic flash point tester

Test material

Constituent 1
Chemical structure
Reference substance name:
2-phenoxyethanol; phosphoric acid
EC Number:
609-691-9
Cas Number:
39464-70-5
Molecular formula:
(C2-H4-O)mult-C6-H6-O.x-H3-O4-P
IUPAC Name:
2-phenoxyethanol; phosphoric acid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: M-1025-157
- Expiration date of the lot/batch: 25 October 2018


Results and discussion

Flash point
Key result
Flash point:
< 200 °C
Remarks on result:
no flash point according to standard method

Any other information on results incl. tables

 Preliminary test was performed from 30 to 200 °C with negative result. The test item was measured in the main test with two parallel tests from 185 °C.

The measured flash point of Ethoxylated phenol phosphate was: no flash point was observed up to 200°C.

Applicant's summary and conclusion

Interpretation of results:
study cannot be used for classification
Conclusions:
The measured flash point of Ethoxylated phenol phosphate was: no flash point was observed up to 200°C using MINIFLASH automatic flash point tester, according to EU A.9.
Executive summary:

The measured flash point of Ethoxylated phenol phosphate was: no flash point was observed up to 200°C using MINIFLASH automatic flash point tester, according to EU A.9.