Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 02 August, 2017 to 05 September, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
photocell detection

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
- Appearance: Colorless liquid
- Purity: 97.5%
- Lot number: 6K0001

Results and discussion

Boiling point
Key result
Boiling pt.:
298.8 °C
Remarks on result:
other: Atmospheric pressure not specified. The determination was under ordinary atmospheric pressure (the detail of the pressure was unknown).

Applicant's summary and conclusion

Conclusions:
The boiling point of the test item is 298.8°C.
Executive summary:

The two measured values of boiling point were within the average value 2 °C. Therefore, it is considered that the results were acceptable.