Registration Dossier

Administrative data

Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 02 August, 2017 to 05 September, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
oscillating densitimeter

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
- Appearance: Colorless liquid
- Purity: 97.5%
- Lot number: 6K0001

Results and discussion

Density
Key result
Type:
density
Density:
0.871 g/cm³
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
Density of the test item was 0.871 g/cm3 (20°C) according to OECD test guideline 109.