Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the flash point is only relevant to liquids and low melting point solids
the study does not need to be conducted because decomposition occurred during the melting point study
Cross-reference
Reason / purpose:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 09, 2015 - January 29, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
yes (incl. certificate)
Type of method:
differential scanning calorimetry
Key result
Decomposition:
yes
Decomp. temp.:
>= 160 °C
Conclusions:
No melting temperature was found between 0 °C and decomposition of the test item starting at about 160 °C.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion