Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
september 2016
Reliability:
1 (reliable without restriction)
Justification for type of information:
The flammability (solids) was determined by measuring the burning rate of test item prepared as a pile of set dimensions. Testing was conducted using a procedure designed to be compatible with Method A.10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
604-144-0
EC Number:
604-144-0
Cas Number:
139525-77-2
Molecular formula:
C13H15NO.HCl
IUPAC Name:
604-144-0
Test material form:
solid: particulate/powder
Details on test material:
White powder
Specific details on test material used for the study:
Batch number : 18113833

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
> 2 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

Preliminary screening

A mould (250 mm long x 20 mm wide x 10 mm high) was loosely filled with test item (tested as received) (previously ground in a pestle and mortar). A non-combustible, non-porous board was placed onto the mould which was then inverted. The mould was removed and an air-rich Bunsen burner flame applied to one end of the pile for two minutes.

Data evaluation

If the test item does not ignite and propagate combustion either by burning with a flame or smoldering along 200 mm within 4 minutes, the test item is not considered as highly flammable and no further testing is required as exploained in the joint document CY78RP.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item melted and failed to ignite during the 2 minutes that the Bunsen flame was applied.
The result of the preliminary screening test obviated the need to perform the main test.

The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.