Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-08-02 to 2016-09-01
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
236 °C
Atm. press.:
101.3 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method is applied for the determination of the flash-point of 4,4'-(1-phenylethane-1,1-diyl)bis(heptyloxybenzene). The flash-point of the substance is 236°C.
Executive summary:

The flash-point of the substance is 236°C.

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
236 °C