Registration Dossier

Ecotoxicological information

Short-term toxicity to fish

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

There is a high probability that the product is not acutely harmful to fish. 

Key value for chemical safety assessment

Additional information

The toxicity of the compound was assessed in a GLP study according to OECD guideline 203. The test was conducated as semi-static test with a single concentration group of 100 mg/L nominal (limit test). Due to the very low water solubiltiy (< 10 µg/L) an analytical concentration control could not be performed. The fish were exposed to a saturated solution of the test item. No effect on the test system was observed at the saturated solution of 100 mg/L after 96 hours. Therefore, the LC0 corresponds to the nominal test item loading rate≥100 mg/L. The LC50 and the LC100 correspond to the nominal test item loading rate >100 mg/L. The NOEC corresponds to a nominal test item loading rate of ≥100 mg/L and the LOEC corresponds to a nominal test item loading rate of > 100 mg/L. No effects could be observed.