Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 Mar - 20 Mar 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
GLP compliance:
yes (incl. QA statement)
Remarks:
Landesamt für Umwelt, Wasserwirtschaft und Gewerbeaufsicht, Mainz, Germany
Type of method:
capillary method

Test material

Constituent 1
Chemical structure
Reference substance name:
{[4-({dimethyl[3-(prop-2-enamido)propyl]azaniumyl}methyl)phenyl]methyl}dimethyl[3-(prop-2-enamido)propyl]azanium dichloride
EC Number:
812-548-5
Cas Number:
1621424-03-0
Molecular formula:
C24H40Cl2N4O2
IUPAC Name:
{[4-({dimethyl[3-(prop-2-enamido)propyl]azaniumyl}methyl)phenyl]methyl}dimethyl[3-(prop-2-enamido)propyl]azanium dichloride

Results and discussion

Melting / freezing point
Decomposition:
yes
Remarks on result:
other: test item decomposed before melting

Any other information on results incl. tables

Results
Pre-test for melting point
Observation of the pre-test for melting point are presented in the following table.

Observations

Temperature (°C)

Test item in aluminium block

19.9

Colour yellow getting darker

210

Colour was light brown

340

Colour brown

350

Colour dark-brown

380

Heating up to 400 °C the test item was black and still solid (test item contracted). The test item decomposed.

 

In the pre-test, the test item showed signs of decomposition before melting indicated by colour change.

The study was terminated. The melting point of the test item could not be determined under these circumstances because of decomposition before melting.

Applicant's summary and conclusion